VE-506B Fully Automatic Vertical Autoclave
VE-506B Fully Automatic Vertical Autoclave

VE-506B Fully Automatic Vertical Autoclave

MOQ : 1 Unit

VE-506B Fully Automatic Vertical Autoclave Specification

  • Type
  • Fully Automatic Vertical Autoclave
  • Chamber Size
  • 500 x 900 mm
  • Chamber Thickness
  • 8 mm (stainless steel)
  • Outer Size
  • 600 x 1100 mm
  • Compressed Air
  • 0.4~0.6Mpa
  • Door Type
  • Vertical Sliding
  • Design Pressure
  • 0.25 MPa
  • Working Pressure
  • 0.22 MPa
  • Design Temperature
  • 139C
  • Heat Uniform
  • 1C
  • Insulation
  • Multi-layer, high-efficiency thermal insulation
  • Net Weight
  • 285 kg
  • Recording Parameters
  • Digital screen, USB data output
  • Spraying Mode
  • Pulse Vacuum Spraying
  • Outer Trolley
  • Stainless Steel
  • Inner Trolley
  • Detachable Tray-Type
  • Spraying Piping
  • Stainless Steel, 360 coverage
  • Steam
  • Saturated Steam
  • Sterilizing Temperature
  • 121C/134C
  • Working Temperature
  • 134C max
  • Sterilization Time
  • 0~99 min adjustable
  • Temperature Scope
  • 105C~134C
  • Piping System
  • Automatic with high-grade valves
  • Valves
  • Electromagnetic & safety valves
  • Power Consumption
  • 9 kW
  • Sterilization Cycle Documentation
  • Integrated printer available
  • Control System
  • Microprocessor based control with multiple cycles
  • Safety Lock
  • Automatic pressure and temperature interlock
  • Exhaust System
  • Automatic with digital regulation
  • Chamber Material
  • SS304 high-grade stainless steel
  • Loading Type
  • Vertical loading with trolley
  • Water Consumption per Cycle
  • 0.3L
  • Alarm System
  • Audio-Visual fault and completion alarms
  • Applicable Use
  • Hospital, Laboratory, Pharmaceutical, Research institutes
  • Power Supply
  • AC 380V/50Hz
  • Display
  • Digital touch control panel
  • Water Supply
  • Automatic/Manual selectable
 

VE-506B Fully Automatic Vertical Autoclave Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Cash in Advance (CID)
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 5-7 Days
  • Main Domestic Market
  • All India
 

About VE-506B Fully Automatic Vertical Autoclave



Introducing the New Release VE-506B Fully Automatic Vertical Autoclave-a crowning achievement in sterilization technology for hospitals, laboratories, pharmaceutical units, and research institutes. Crafted from potent SS304 high-grade stainless steel, this unrivaled autoclave delivers consistent results with digital touch control, microprocessor precision, and multi-layer insulation. Enjoy reduced water and energy consumption per cycle, alongside advanced safety features and audio-visual alarms. Order today and experience an industry-leading solution that ensures faultless sterilization for all your critical applications.

VE-506B Autoclave: Robust Applications Across Industries

Tailored for high-performance applications, the VE-506B is ideally suited for medical, pharmaceutical, laboratory, and research environments. Its vertical loading with trolley and adjustable temperature make it perfect for diverse sterilization needs such as instruments, glassware, liquids, and culture media. Designed for repeated, intensive usage, it offers reliable sterilization across every application surface, supported by durable stainless steel construction and a versatile cycle selection.


Efficient Export and Timely Delivery-VE-506B Autoclave

Our VE-506B Autoclave is offered FOB Port India with estimated delivery times based on your location and order size. We prioritize prompt delivery to major export markets including Asia, Africa, and the Middle East. Get a reliable estimate for your order-our team ensures every shipment meets international standards, with comprehensive support throughout the offer, dispatch, and installation phases for a seamless global purchase experience.


FAQ's of VE-506B Fully Automatic Vertical Autoclave:


Q: How does the VE-506B Fully Automatic Vertical Autoclave ensure a uniform sterilization process?

A: The VE-506B utilizes pulse vacuum spraying, multi-layer insulation, and a 360 coverage spraying piping system, guaranteeing consistent heat distribution and unrivaled sterilization efficacy.

Q: What type of applications is the VE-506B Autoclave suitable for?

A: This autoclave is tailored for hospitals, laboratories, pharmaceutical companies, and research institutes-capable of sterilizing instruments, liquids, glassware, and other laboratory essentials with ease.

Q: Where can I view the sterilization data and cycle documentation?

A: Sterilization parameters and cycle documentation can be monitored via the digital display, while records are easily exported using the integrated USB data output or the built-in printer.

Q: What benefits does the microprocessor-based control system offer?

A: The microprocessor enables multiple programmable cycles, precise temperature and pressure regulation, automatic fault detection, and user-friendly operation via the digital touch control panel.

Q: When is the best time to replace the autoclave's water supply or check its status?

A: The VE-506B features both automatic and manual water supply selection and alerts users with audio-visual alarms when maintenance or refilling is required.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Automatic Autoclave Category

HR-HRD-508 Horizontal Rectangular Autoclave

HR-HRD-508 Horizontal Rectangular Autoclave

Minimum Order Quantity : 1 Unit

Design Pressure : 2.45 bar (absolute)

Sterilizing Temperature : 121C 134C

Power Consumption : 712 kW depending on model/configuration

Working Pressure : 2.1 bar (absolute)

Valves : Imported pneumatic & manual safety valves

HRSS-HRSD-508C Rectangular Sliding Double Door Autoclave

HRSS-HRSD-508C Rectangular Sliding Double Door Autoclave

Minimum Order Quantity : 1 Unit

Design Pressure : 0.25 MPa

Sterilizing Temperature : 121C or 134C

Power Consumption : 9.5 kW

Working Pressure : 0.22 MPa

Valves : Automatic Pneumatic & Manual Safety Valves

Rectangular Autoclav

Rectangular Autoclav

Minimum Order Quantity : 1 Unit

Design Pressure : 2.5 bar

Sterilizing Temperature : 121C to 134C

Power Consumption : 12 kW

Working Pressure : 2.1 bar

Valves : Automatic safety and steam release valves

Sliding Door Autoclav

Sliding Door Autoclav

Minimum Order Quantity : 1 Unit

Design Pressure : 2.5 bar

Sterilizing Temperature : 121C 134C

Power Consumption : 1018 kW depending on chamber size

Working Pressure : 1.22.2 bar

Valves : Pneumatic and manual safety valves