Industrial Vertical Autoclave (VC-506 ) Specification

  • Type
  • Vertical Cylindrical
  • Chamber Size
  • 400 x 600 mm
  • Chamber Thickness
  • 4-6 mm (SS304)
  • Outer Size
  • 610 x 910 mm
  • Door Type
  • Radial Locking System/Manual
  • Design Pressure
  • 2.2 Kg/cm2
  • Working Pressure
  • 1.2 Kg/cm2
  • Design Temperature
  • 138C
  • Heat Uniform
  • 1C
  • Insulation
  • High density glass wool
  • Net Weight
  • Approx 170 kg
  • Recording Parameters
  • Digital Temperature Controller & Recorder
  • Spraying Mode
  • Vertical/Direct Steam
  • Outer Trolley
  • Provided (Removable)
  • Inner Trolley
  • Stainless Steel Trolley Included
  • Spraying Piping
  • Stainless Steel Piping
  • Steam
  • Saturated Steam
  • Sterilizing Temperature
  • 121C - 134C
  • Working Temperature
  • 121C - 134C
  • Sterilization Time
  • 0-999 min (Adjustable)
  • Temperature Scope
  • Room temp to 134C
  • Piping System
  • SS304/SS316
  • Valves
  • Safety Valve, Steam Release Valve, Vacuum Valve
  • Power Consumption
  • 4.5 KW
  • Display
  • Digital LED/LCD
  • Pressure Gauge
  • Analog Bourdon Type
  • Application
  • Laboratory, Medical, Pharmaceutical, Research
  • Timing Control
  • Programmable Digital Timer
  • Gasket Material
  • Silicon/Neoprene
  • Mounting
  • Castor wheels for easy movement
  • Voltage Supply
  • 220V/50Hz AC
  • Chamber Material
  • Stainless Steel (SS304/SS316)
  • Control System
  • Fully Automatic, PLC based panel
  • Water Filling
  • Manual/Automatic
  • Heating Element
  • Heavy Duty Immersion type
 

Industrial Vertical Autoclave (VC-506 ) Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 10 Pieces Per Week
  • Delivery Time
  • 7 Days
 

About Industrial Vertical Autoclave (VC-506 )



Experience first-string sterilization with the latest Industrial Vertical Autoclave (VC-506). Crafted from exquisite stainless steel (SS304/SS316), this kingly autoclave guarantees peak performance in laboratory, medical, pharmaceutical, and research settings. Featuring a heavy-duty immersion-type heating element and a programmable digital timer, it offers both reliability and precision. Benefit from a fully automatic, PLC-based panel with digital LED/LCD display for supreme control. The silicon/neoprene gasket ensures durability, while castor wheels provide effortless movement. Promotion: Order today from India's leading manufacturer and supplier to elevate your sterilization standards!

Advanced Use and Commercial Applications

The Industrial Vertical Autoclave (VC-506) is tailored for rigorous laboratory, medical, pharmaceutical, and research applications. Its robust build accommodates high-frequency commercial use, ensuring thorough sterilization of equipment and media. Key features include an analog Bourdon-type pressure gauge, programmable digital timer, and manual or automatic water filling. Designed for professional environments, it delivers unmatched reliability and operational efficiency.


Certifications, Delivery, and Premium Shipment Services

All units are manufactured in line with recognized certifications, ensuring safety and quality compliance. Sample autoclaves are available for evaluation, and prompt delivery times are assured through dependable transport services. Each autoclave shipment is carefully handled to guarantee safe arrival. Benefit from our premium shipment, with the assurance of seamless transport across India-order today for quick and secure service!


FAQ's of Industrial Vertical Autoclave (VC-506 ):


Q: How does the programmable digital timer enhance autoclave operation?

A: The programmable digital timer allows users to set precise sterilization durations, ensuring optimal efficacy and consistency in the sterilization process for various applications.

Q: What are the primary benefits of using the VC-506 autoclave in laboratories and research facilities?

A: The VC-506 provides efficient, reliable, and safe sterilization, critical for maintaining contamination-free environments in labs, medical institutions, and pharmaceutical production.

Q: Where can the Industrial Vertical Autoclave (VC-506) be utilized?

A: It is ideal for use in laboratories, hospitals, pharmaceutical plants, and research centers that require stringent sterilization processes.

Q: When should water filling be selected as manual or automatic?

A: Manual water filling is suitable for precise control during specialized tasks, while automatic water filling offers convenience and time-saving for routine operations.

Q: What makes the VC-506 a premium choice among laboratory autoclaves?

A: Its construction from durable stainless steel, fully automatic PLC controls, heavy-duty heating elements, and castor-mounted mobility position it as a first-string, kingly option.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Automatic Autoclave Category

Industrial HRSS-HRSD-508C Rectangular Sliding Double Door Autoclave

Industrial HRSS-HRSD-508C Rectangular Sliding Double Door Autoclave

Minimum Order Quantity : 1 Unit

Inner Trolley : Stainless Steel (SUS304)

Design Pressure : 0.25 MPa

Power Consumption : 9.5 kW

Chamber Thickness : 8 mm stainless steel

Temperature Scope : 105C ~ 138C

Industrial Horizontal Rectangular Single Sliding  Door Autoclave (Hrs-508C)

Industrial Horizontal Rectangular Single Sliding Door Autoclave (Hrs-508C)

Minimum Order Quantity : 1 Piece

Inner Trolley : Removable type stainless steel

Design Pressure : 2.5 bar

Power Consumption : Approx. 1218 kW depending on model size

Chamber Thickness : 1016 mm depending on capacity

Temperature Scope : 105C to 134C

Industrial Horizontal Rectangular Autoclave (HR-508 )

Industrial Horizontal Rectangular Autoclave (HR-508 )

Minimum Order Quantity : 1 Unit

Inner Trolley : Stainless Steel, Removable

Design Pressure : 2.5 kg/cm2

Power Consumption : 812 KW (Depending on Model)

Chamber Thickness : 1012 mm (SS316)

Temperature Scope : Ambient to 134C

Industrial Vertical Autoclave Fully Automatic   Vc-506B

Industrial Vertical Autoclave Fully Automatic Vc-506B

Minimum Order Quantity : 1 Piece

Inner Trolley : Provided

Design Pressure : 0.24 MPa

Power Consumption : 6 KW

Chamber Thickness : 6 mm (SS304)

Temperature Scope : 105C to 134C



Back to top